Specifications for Telephone Drop Wire

(Hard Drawn Copper)



SIZE AWG #18/2 AWG #17/2 AWG #17/2
CONDUCTORS Parallel Parallel Twisted
Diameter, mm 2C X 1.020mm 2C X 1.15mm 2C X 1.15mm
max. 1.05mm max. 1.16mm max. 1.16mm
min. 0.96mm min. 1.138mm min. 1.138mm
Resistivity, ohm-mm2/m 0.01793 max. 0.01793 max. 0.01793 max.
Conductivity per conductor, % 96.16 min. 96.16 min. 96.16 min.
Elongation per conductor, % 0.85 nominal 1.0 nominal 1.0 nominal
Tensile strength, kg/mm2 47.1 nominal 48.42 nominal 48.42 nominal
Insulated dimension: Major Diameter, mm 8.05 8.3 4.40
Insulated dimension: Minor Diameter, mm 4.75 4.15 n/a

Reference:
1. REA PE -7, Specification for Parallel Conductor Drop Wire for Aerial Application
2. ASTM B 1, Standard Specification for Hard-Drawn Copper Wire



Specifications for Telephone Drop Wire
(Copper-Clad Steel Wire)

SIZE #18/2 awg
Conductor Parallel
Grade of Wire Grade 30 HS
High strength,30% conductivity
Diameter 2C x 1.020mm nominal
max. +0.030 mm
min. -0.060 mm
Resistance, ohm/km 80.40 max @ 20oC
Breaking strength 760 Newton (77.5 kg)
Elongation 1.5% minimum
Thickness of copper clad 0.1016 mm minimum
Insulation material PE BLK
Insulated Dimensions
Minimum thickness @ any point 1.0 mm
Major diameter 5.5 to 8.0 mm
Minor diameter 3.0 to 5.0 mm

Reference:
1. Rural Electrification Administration (REA), BULLETIN 345-36 PE-7, Specification for Parallel Conductor Drop Wire for Aerial Application
2. ASTM B 227, Standard Specification for Hard-Drawn Copper-Clad Steel Wire